Performance characteristics: 1. High-precision, low resistance, to reverse zero clearance and linear low driving force to ensure extended service life; 2. High-precision control and repeatable measurement results ensure a more realistic reflection of the specimen characteristics; 3. Four-column double-screw double space rigid frame structure, linear travel to ensure the crosshead neutral, thereby reducing test data error, raise experimental accuracy; 4. The digital closed-loop position control servo motor and gear reducer drive mechanism, the servo motor having a large torque output can be realized in a wider load range of high-precision speed control, quick response and full performance; 5. The high degree of intelligence system has a self-diagnostic function. It can automatically detects over-voltage, over-current, over-temperature; 6. Automatic hydraulic grip prevents sample slippage. The adjustable gripping pressure prevents damage to the soft material specimen to improve the accuracy of test results; 7. Optional double cylinder synchronous hydraulic grip, huge clamping force, specimen doesn’t slip. The adjustable pressure to prevent damage to the soft material sample, improving the accuracy of the test results; 8. High-precision tension and compression bi-directional load cell, strong resistance to lateral and impact; 9. There are dozens of different types of fixtures, to meet the different requirements of various industries material testing; 10. Aluminum cover for easy cleaning and a long-lasting-life;
Applications: Metal wire, strip, bar, tube,l sheet; Rebar, strand;l
Applied Standards: Load meets or exceeds the following standards: ASTM E4, ISO7500-1, EN10002-2, BS1610, DIN 51221. Strain measurement meets or exceeds the following standard: ASTM E83, ISO 9513, BS3846, EN10002-4
1、main engine
Max. load |
2000kN |
measuring range |
1%~100%FS |
Force resolution |
0.01kN,full scale0-2000kN |
accuracy class |
0.5 class, 20-2000kN;
1 class,4-2000kN; |
Accuracy of test force indication |
±0.5%, |
Test force resolution |
500000 yards |
Accuracy of displacement indication |
±0.5% |
Beam displacement resolution |
0.5μm |
Beam displacement accuracy |
10 when ≤ 5mm μ m. ± 0.5% at ≥ 5mm |
Deformation measurement range |
1%~100%F·S |
Accuracy of deformation indication |
±0.5% |
sampling frequency |
100Hz |
Stress rate range |
1~60 (N/mm2) s-1 |
Strain rate range |
0.00025/s~0.0025/s |
Maximum test speed |
0.005-400 mm/min |
Effective distance between columns |
≥1100mm |
Maximum effective spacing between stretching chucks (including jaw seats) |
1000m |
Circular specimen clamping diameter |
Φ15-65mm |
Clamping thickness of flat specimen |
2-60mm |
Load frame dimension(mm) |
2000x1160x4370 |
Weight(kg) |
About14000 |
2、Flat pushing fixture
Maximum test load |
2000kN |
Maximum clamping force |
3000kN |
Maximum hydraulic pressure |
48MPa |
Clamping range of bar specimens |
Φ15~65mm |
Clamping thickness of flat specimen |
2~60mm |
|